Portable, Reliable & Wireless Pulse Oximeter
|
|
Our Product
PULOX2000 Operation Scope
The fingertip Oximeter can be used to measure human Hemoglobin Saturation and heart rate through the fingertip.
The product is suitable for home use, Medical - clinical, Anesthesia, pediatrics, intensive care, physical care in sports etc.
The product is not suitable to monitor patients continuously.
The PULOX2000 implements a Spot Oxygen Saturation (SPO2) method - SPO2 means, that the oxygen saturation levels are being measured repeatedly, every few milliseconds. Each measure gives a Spot-like image of current oxygen saturation level.
 Buy Now €169.99
Features
- SpO2 & pulse monitoring, and histogram & bar graph display of pulse rate.
- 24 hour data storage.
- USB data transmission (a CD containing a PC software and USB driver is included).
- LCD graphic display with back light.
- Multi-direction display (4 modes).
- Color Display.
- 4 levels on brightness.
- Easy to use & high accuracy and repetition.
- Automatic power-off after 5 seconds of idle signal.
- Light weight (50g), battery included, small size, portable.
- Long time continuous use (12 h) with a rechargeable lithium battery.
- Low voltage alarm display.
Old Generation SpO2 |
New Generation SpO2 (PULOX2000) |
| One reading per use |
Continuous spot readings |
| 1 way display |
4 way OLED display |
No data storage |
24 hour data storage |
No data transmission |
USB data transmission |
Short energy span |
Long lasting battery |
Numeric BPM display |
BPM numeric & graphic display |
Expensive prototypes |
Cost effective |
Local disributors |
Worldwide shipping |
Advantages
- Operation of the pulse oximeter is simple and convenient.
- The Spo2 device is compact and ultra light (total weight is about 50g including battery) and conveniently carried.
- 24 hour data storage and USB transmission allow data monitoring by the included PC software.
- Economic power consumption (the rechargeable lithium battery can be operated continuously for 12 hours).
- Low voltage warning will be indicated in the visual display when battery voltage is low.
- The product will automatically be powered off when out of use for longer than 5 seconds.
(Learn more about Pulse Oximetry)
 Buy Now €169.99
Pulse oximetry uses a light emitter with red and infrared LEDs that shines through a reasonably translucent site with good blood flow. Typical adult/pediatric sites are the finger, toe, pinna (top) or lobe of the ear. Infant sites are the foot or palm of the hand and the big toe or thumb. Opposite the emitter is a photodetector that receives the light that passes through the measuring site.
Specifications
Display
|
Type |
LCD display |
4 display modes |
Parameters |
SpO2, PR, Pleth bar. Pleth waveform. |
Information |
Low Battery |
4 levels on brightness
|
|
Patient Range |
Adult |
Pediatric |
|
SpO2 |
Range |
35%-100% |
Resolution |
1% |
Accuracy |
70% to 100% ±2 digits |
|
0%-69%: unspecified |
Method |
Dual wavelength LED |
|
Heart (Pulse) Rate |
Range |
|
Resolution |
1bpm Accuracy |
|
±2bpm or ±2% |
|
Environmental |
Operating Temperature |
10°C-40°C (50°F-104°F) |
Storage Temperature
|
-20°C - 55°C (-4°F-131°F) |
Operating Humidity |
35%RH - 75%RH |
Storage Humidity |
less than 95%RH |
|
Classification |
Safety
|
Class IIA (MDD93/42/EEC IX Rule 10) |
|
Mechanical |
Size
|
57 x 32 x 30 mm |
Weight |
50g (including battery) |
|
Battery |
Type
|
Lithium polymer rechargeable battery (by USB)
|
Operation time |
minimum 12 hours for normal Operation |
|
|